IDEAL ADMINISTRATION
Version 26.8.5

FAQ

Windows Active Directory Reporting and Audits

How to write Active Directory audit alerts to the Windows event log?

We collect Windows logs in our monitoring tool (SIEM, event collector...).

Can the Real Time Audits alerts of IDEAL Administration be written to the Windows event log?

Yes, starting with version 27.0. For each audit concerned:

  1. In the Active Directory Network tab, Real Time Audits sub-tab, click Action > Configure.
  2. Select the audit, then Action > Alert.
  3. Check Alert, set the condition and the alert level.
  4. In the Notifications frame, check Write an event to the Windows Application log.

This option can be combined with email notification.

Events written

The event is written to the Application log of the computer running IDEAL Administration, with the source IDEAL Administration. Its ID depends on the alert level:

IDAlert levelEvent type
1000 Information Information
1001 Warning Warning
1002 Critical Error
1003 Security / Urgent Error
1010 Alert email could not be sent, or email not configured Warning

The event text matches the email: level, category, audit, value found, Active Directory path, server, date and detecting computer.

You can then collect these events with your SIEM or Windows Event Forwarding, or trigger a scheduled task on a specific ID (for example a script started on event ID 1003).

Note: on the first event, IDEAL Administration registers the IDEAL Administration source in the computer's registry. Run the software once with local administrator rights: without this registration, events are still written, but Event Viewer shows a "description cannot be found" warning.

Letzte Änderung: 22/11/2026

Möchten Sie es selbst überprüfen? Testen Sie IDEAL ADMINISTRATION 30 Tage lang kostenlos.

30-TAGE-TESTVERSION HERUNTERLADEN